3. Presser lifting, Lowering frequency vertical times setup
Press the
and
B0: Ineffective (Initial value)
B1 ~ B10: 1 to 10 times
After setting, press the
4. Continuous operation
After the completion of setting, regular operation like pattern number setup and others should be carried out.
At the end of sewing, origin retrieval of each motor is carried out for the X/Y / presser and thread trimmer /
needle thread clamp if "origin retrieval effective" has been selected as per 2. Then, automatic sewing is
restarted after the lapse of the rest time preset as per 1. above.
To stop continuous operation, the start switch should be turned ON during the rest time. [E 50] is displayed
and the machine is stopped.
keys to set up the presser vertical times.
key. The ordinary display is recovered.