(2) Changing the voltage specification

It is adaptable to the voltage of single phase 100V to 120V/3-phase 200V to 240V by changing the voltage changeover
connector mounted on FLT-T p.c.b.
(Caution) When the changing procedure is wrong, the control box will be broken. So, be very careful.
A
WHITE
BLACK
RED
GREEN/
YELLOW
B
WHITE
BLACK
RED
GREEN/
YELLOW
C
WHITE
BLACK
RED
GREEN/
YELLOW
(Plug side)
WHITE
BLACK
RED
GREEN/
YELLOW
(Plug side)
WHITE
BLACK
RED
GREEN/
YELLOW
(Plug side)
WHITE
BLACK
RED
GREEN/
YELLOW
– 186 –
Changing procedure of the changeover connector
1. Turn OFF the power source with the power switch
after confirming that the sewing machine has stopped.
2. Draw out the power cord from the power plug socket
after confirming that the power switch is turned OFF.
Then wait for five minutes or more.
3. Remove the front cover.
4. Remove four screws fixing the rear cover of the con-
trol box and slowly open the rear cover.
A. In case of using with 3-phase 200V to 240V
Changing the changeover connector
Connect to 200V the 100/200V changeover connec-
tor of FLT-T p.c.b.
Side of the control box.
Connect the crimp style terminal of AC input cord to
the power plug as shown in the figure.
B. In case of using with single phase 100V to 120V
Changing the changeover connector
Connect to 100V the 100/200V changeover connec-
tor of FLT-T p.c.b.
Side of the control box.
Connect the crimp style terminal of AC input cord to
the power plug as shown in the figure.
(Caution) Securely perform the insulation treatment
to the red terminal which is not used with
insulation tape or the like. (When the in-
sulation is insufficient, there is a danger
of electric shock or leakage current.)
C. In case of using with single phase 200V to 240V
• Changing the changeover connector
Connect to 200V the 100/200V changeover connec-
tor of FLT-T p.c.b.
Side of the control box.
Connect the crimp style terminal of AC input cord to
the power plug as shown in the figure.
(Caution) Securely perform the insulation treatment
to the red terminal which is not used with
insulation tape or the like. (When the in-
sulation is insufficient, there is a danger
of electric shock or leakage current.)
5. Check that the change has been performed without
fail before closing the rear cover.
6. Be careful that the cord is not pinched between the
rear cover and the control box main unit.
Close the rear cover while pressing the lower side of
rear cover, and tighten four screws.
located on the side of the Box
located on the side of the Box
located on the side of the Box