9) Method of needle thread clamp motor / origin sen-
sor check
1. Display of the needle thread clamp motor / origin
sensor check screen is displayed.
When the needle thread clamp motor / origin sensor
check button
program screen, the needle thread clamp motor /
origin sensor check screen is displayed.
2. Needle thread clamp motor / origin sensor check
According to the status of the needle thread clamp
sensor, the ON/OFF condition of the needle thread
clamp origin sensor is displayed in the position of C.
According to the status of the needle thread clamp
origin sensor, the ON/OFF condition of the needle
thread clamp sensor is displayed in the position of
B.
Using the [+] and [–] buttons
needle thread clamp motor can be driven by one
pulse.
When the fixed position moving button
pressed, the needle thread clamp motor is driven to
any of the following fixed positions. A pictograph in-
dicating this position is reversed and displayed.
G : Standby position (front side)
H : Needle thread bending position
I : Needle thread clamp position
J : Refuge position (rear side)
Using the Start SW, origin retrieval of the needle
thread clamp motor is effected.
(Caution) The Start Switch becomes effective after
the completion of origin retrieval for the
needle thread clamp motor.
– 162 –