Port I/O Setup - JUKI AMS-210E Series Engineer's Manual

Hide thumbs Also See for AMS-210E Series:
Table of Contents

Advertisement

(4) Port I/O setup

This sewing machine is provided with the machine control functions that are enabled only by the machine main body
through the generation of signal outputs to the outside and the reception of signal inputs from the outside, without
the intervention by any appropriative I/O unit and other devices.
By making connections with proper external sequencers (programmable controllers) or using the simplified se-
quencer functions that are available at the main body, the machine is possible to be modified into a mechanical
system of various annex units.
1. Input terminal setup
Input No.
Contents
0
Nil
For the actuator
1
Void
2
Detection of material end
sensor
3
Bank input 0
4
Bank input 1
5
Bank input 2
6
Bank input 3
For pattern data inputs
33
External input 0
34
External input 1
35
External input 2
36
External input 3
37
External input 4
38
External input 5
39
External input 6
40
External input 7
41
External input 8
42
External input 9
43
External input 10
44
External input 11
45
External input 12
46
External input 13
47
External input 14
48
External input 15
Operation prohibit / weight request
49
Presser SW input prohibited
50
Start SW input prohibited
51
Sewing start wait
52
XY motor start wait
53
Sewing machine start wait
54
Sewing machine stop wait
55
Feeding frame vertical motion Total lifting and lowering of the feeding frame is suspended in active phase. Total lifting and
wait
No input
Detection of material end is enabled with the first Mark 1 command of the pattern data.
When the input terminal becomes active, the section to the second Mark 1 command is skipped.
Input terminal 0 when the bank function is selected
Input terminal 1 when the bank function is selected
Input terminal 2 when the bank function is selected
Input terminal 3 when the bank function is selected
Sewing is suspended until the input terminal becomes active with the External Input 0 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 1 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 2 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 3 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 4 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 5 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 6 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 7 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 8 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 9 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 10 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 11 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 12 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 13 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 14 com-
mand of the pattern data.
Sewing is suspended until the input terminal becomes active with the External Input 15 com-
mand of the pattern data.
Entry of presser switch 1 to 4 inputs is prohibited in active phase.
Entry of start switch inputs is prohibited in active phase.
Start of sewing start switch operation is waited in active phase. Sewing is started in non-
active phase. This signal is disregarded in the middle of sewing.
Start of XY motor driving is waited in active phase. The XY motor driving is started in non-
active phase. This signal is disregarded in the middle of XY motor driving.
Start of sewing machine head rotation is waited in active phase. Intermediate presser lower-
ing and sewing machine head rotation are started in non-active phase. Upper position reset
is not included. This signal is disregarded in the middle of sewing machine head driving.
Operation is suspended after the stoppage of sewing machine head rotation and wiper and
intermediate presser lifting operation in active phase. Subsequent operation is started in
non-active phase. Upper position reset is not included. This signal is disregarded in the middle
of sewing machine head driving.
lowering of the feeding frame is performed in non-active phase. Feeding frame lifting and
lowering are not included at the time of presser pedal operation.
– 101 –
Explanation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents