(2) Method of mechanical valve unit connections

Stop plug
B
A
Connector
Stop plug
CN2
A
Connector
CN1
1. Remove once two setscrews
, two spring washers
attached to mechanical valve unit
figure, and install 2-pedal (PK78) type
of mechanical valve unit
2. Connect the air tubes
machine head, to the Y-type joint
o Air tube
→ Y-type joint
of mechanical valve unit
o Air tube
→ Y-type joint
of mechanical valve unit
3. Install the air tube coming from mechanical valve unit
"7" to
, and that from "8" to
A
Attach two accessory stop plugs and the cords com-
ing from the control box to the connectors CN1, CN2,
respectively.
4. Connect solenoid valve asm.
using long air tube supplied
(Caution) When the cable sage, fix it to the table us-
ing the staple supplied with the machine
as accessories.
– 184 –
, two washers (small)
and two washers (large)
.
,
which come from the
,
with label of "1A, 2A"
connected with the label of "3"
with label of "1B, 2B"
connected with the label of "4"
respectively.
B
and the regulator
as accessories.
. Refer to the
into hole A
respectively.