JUKI AMS-210E Series Engineer's Manual page 57

Hide thumbs Also See for AMS-210E Series:
Table of Contents

Advertisement

Adjustment Procedures
1. Make an origin setting gauge
to the work clamp foot
Adjustment Procedures
1. Start the test mode I06 (IP-400), or CP-2 (CP-20).
2. When the star pedal is depressed, the feed moves to the mechanical
origin and stops.
3. Lower the needle and check the right and left displacement based on
the engraved marking of the origin.
4. When the engraved marking of the origin is found to be displaced in
Direction A from the needle tip, loosen the two set screws
adjust the sensor mounting plate
tighten the two set screws
5. When the engraved marking of the origin is found to be displaced in
Direction B from the needle tip, loosen the two set screws
adjust the sensor mounting plate
tighten the two set screws
(Caution) After the adjustment, make sure that the slit plate does
not interfere with the sensor
as shown in the figure, and attach it
.
in Direction C. After adjustments,
.
in Direction D. After adjustments,
.
.
and
and
– 52 –
Results of Improper Adjustment
Results of Improper Adjustment