Adjustment Procedures
1. Remove 4 set screws
the old presser plate sheet
2. After mounting the presser plate
with 4 set screws
to the presser plate
to remove the presser plate
with new one.
, adjust the height of the slider
. To position the height, lightly press the slider
when the presser goes up.
, and replace
o If the position where the presser
o Wrong slider
– 48 –
Results of Improper Adjustment
plate sheet
was pasted is
wrong, abrasion of related
components or peeling of the
presser plate sheet
resulting in a feed error due to
direct contact between the slider
and presser plate
height may cause
a feed error.
may occur
.