Error code
E903
E904
E905
E907
E908
E910
E913
E914
E915
E916
E917
Pict
Abnormality of stepping motor power
When stepping motor power of servo control p.c.b.
fluctuates ±15% or more.
Abnormality of solenoid power
When solenoid power of servo control p.c.b.
fluctuates ±15% or more.
Heat sink temperature for SERVO CONTROL p.c.b. Turn OFF
fabnormality
Turn ON the power again after taking overheat time
of SERVO CONTROL p.c.b.
X feed motor origin retrieval error
When origin sensor signal is not inputted at the time
of origin retrieval motion.
Y-feed motor origin retrieval error
When origin sensor signal is not inputted at the
time of origin retrieval motion.
Presser motor origin retrieval error
When origin sensor signal is not inputted at the
time of origin retrieval motion.
Thread clamp origin retrieval error
When origin sensor signal is not inputted at the time
of origin retrieval motion.
Feed defective error
Timing lag between feed and main shaft occurs.
Abnormality of communication between
operation panel and main CPU
When abnormality occurs in data communication.
Abnormality of communication between main
CPU and main shaft CPU
When abnormality occurs in data communication.
Failure of communication between operation
panel and personal computer
When abnormality occurs in data communication.
Description of error
– 203 –
How to recover Place of recovery
Turn OFF
the power.
Turn OFF
the power.
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Possible to
re-start after
reset.

Hide quick links: