14.7 Disassembly and Replacement

[A]
Transfer belt unit / Transfer belt cleaning unit
Note:
It is recommended to wear gloves to avoid a direct touch on the belt surface.
(1)
Take off the process unit (
Process unit").
(2)
Remove 2 screws on the front side.
(3)
Remove 2 screws (shoulder screw) on the
rear side.
(4)
Disconnect 1 connector on the rear side.
(5)
Take off the transfer belt.
Note:
When the transfer belt unit is being installed,
screw the unit by pressing it downward.
e-STUDIO281c/351c/451c
TRANSFER UNIT
P.11-10 "[B]
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
14 - 8
05/08
Fig. 14-3
Connector
Fig. 14-4
Transfer belt unit