When the paper in the drawer gets short during copying,
The tray-up sensor turned OFF
The tray-up motor turned ON - Tray goes up
Tray-up sensor turned ON
Tray-up motor stopped
Empty sensor turned OFF during the copying in spite of the tray-up sensor is ON
(B) Paper misfeed in bypas
During bypass feeding
Bypass feed clutch (CLT6) is turned ON
Registration sensor (S22) is turned ON
* Registration sensor (S22) is not turned ON in a fixed period of time (E120)
Bypass misfeeding
Bypass misfeed symbol is displayed
The copying operation is disabled.
Solution: The bypass sensor (S35) is turned OFF by removing the paper from the bypass tray.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
It is judged that there is no paper.
Drawer area of the control panel blinks.
(When the drawer is selected)
The copying operation is stopped.
4 - 11
e-STUDIO281c/351c/451c
GENERAL OPERATION