Toshiba e-STUDIO281c Service Manual page 363

Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

Note:
Install the oil roller according to the marking
on the frame (the shaft end with a groove
should point at the rear side).
[C] Cleaning roller
(1)
Take off the oil roller from the cleaning unit
(
P.16-19 "[B] Oil roller").
(2)
Remove 1 E-ring and 1 bushing from the
cleaning roller front side. Then take off the
cleaning roller.
(3)
Remove the spring (B) on each end of the
frame.
Note:
When installing, make sure that the oil roller
rotates smoothly by turning the gear (C) of
the cleaning roller manually for a several
times.
(4)
Remove 1 E-ring, the gear (C) and 1 bushing
from the cleaning roller rear side.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Oil roller
Fig. 16-16
Cleaning roller
E-ring
Bushing
Fig. 16-17
Fig. 16-18
16 - 21
Groove
Gear ( C )
Spring ( B )
Bushing
Gear ( C )
E-ring
e-STUDIO281c/351c/451c