[H] Transfer belt cleaner auger motor (M2)
(1)
Take off the process unit
(
P.11-10 "[B] Process unit").
(2)
Disconnect 1 connector and remove 1 har-
ness clamp itself.
(3)
Remove 2 screws and take off the transfer
belt cleaner auger motor with its bracket.
(4)
Remove 2 screws and take off the transfer
belt cleaner auger motor from its bracket.
[I]
2nd transfer roller
(1)
Open the 2nd transfer unit.
(2)
Remove 1 clip, 1 collar (with bearing), 1
washer and 1 bushing (with bearing) on the
front side of the 2nd transfer roller.
(3)
Remove 1 clip and slide 1 bushing (with
bearing) on the rear side of the 2nd transfer
roller.
(4)
Take off the 2nd transfer roller.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved