Sign In
Upload
Manuals
Brands
WAGO Manuals
I/O Systems
753-1631
WAGO 753-1631 Manuals
Manuals and User Guides for WAGO 753-1631. We have
2
WAGO 753-1631 manuals available for free PDF download: Manual, Product Manual
WAGO 753-1631 Manual (64 pages)
SMI Master Module 230 V AC
Brand:
WAGO
| Category:
Control Unit
| Size: 3.15 MB
Table of Contents
Table of Contents
3
1 Notes about this Documentation
5
Validity of this Documentation
5
Copyright
5
Symbols
6
Number Notation
8
Font Conventions
8
Table 1: Number Notation
8
Table 2: Font Conventions
8
2 Important Notes
9
Legal Bases
9
Subject to Changes
9
Personnel Qualifications
9
Use of the WAGO-I/O-SYSTEM 750 in Compliance with Underlying Provisions
9
Technical Condition of Specified Devices
10
Disposal
10
Safety Advice (Precautions)
11
3 Device Description
13
Table 3: Compatibility List 753-1630 - Full Mode
14
Table 4: Compatibility List 753-1630 - Fieldbus Coupler Mode
15
View
16
Figure 1: View of Device
16
Table 5: Legend for Figure "View
16
Connectors
17
Data Contacts/Local Bus
17
Figure 2: Data Contacts
17
Power Jumper Contacts/Field Supply
18
Figure 3: Power Jumper Contacts
18
Table 6: Legend for Figure "Power Jumper Contacts
18
CAGE CLAMP ® Connectors
19
Function Earth
19
Figure 4: CAGE CLAMP ® Connections
19
Table 7: Legend for "CAGE CLAMP ® Connections" Figure
19
Display Elements
20
Figure 5: Display Elements
20
Table 8: Legend for the "Display Elements" Figure
20
Schematic Diagram
21
Figure 6: Schematic Circuit Diagram
21
Technical Data
22
Device Data
22
Power Supply
22
Table 9: Technical Data - Device
22
Table 10: Technical Data - Power Supply
22
Communication
23
Table 11: Technical Data - Communication
23
Table 12: Technical Data - Field Wiring
23
Climatic Environmental Conditions
24
Table 13: Technical Data - Climatic Environmental Conditions
24
Approvals
25
Standards and Guidelines
26
4 Function Description
27
Fieldbus Coupler Mode
27
Digital Input
28
1-Button Operation/Construction Site Mode
28
Forced Position
29
2-Button Operation
29
Positioning Curtains and Slats
30
Table 14: Behavior of SMI Drives and Curtains with Button Presses
30
Figure 7: Schematic Representation of the Positioning of Shutters and Slats
31
Table 15: Legend for the Figure "Schematic Representation of the Positioning of Shutters and Slats
31
Controller Locking
32
Energy Saving Mode
32
Activating the Energy Saving Function Via Timeout
32
Activating the Energy Saving Function Via Control Byte C1
33
Digital Output
33
Local Bus Failure Monitoring
34
Controller Failure Monitoring
34
Power Failure Monitoring
34
Automatic Addressing
35
Auto-Replace
35
Full Mode
37
System Extensions
37
Switching Addresses and Readdressing
37
Logging
38
Reading the System Image
38
Extended SMI Command Set
38
5 Process Image
39
Control/Status Byte
40
Table 16: Control Byte C0
40
Table 17: Status Byte S0
40
Extended Control/Status Byte
41
Table 18: Control Byte C1
41
Table 19: Status Byte S1
41
Fieldbus Coupler Mode
42
Output and Input Process Image
42
Table 20: Output and Input Process Image in Fieldbus Coupler Mode
42
Addressing SMI Drives
43
SMI Commands
44
Table 21: SMI Commands
44
Table 22: Response to Request Commands
45
Full Mode
46
6 Mounting
47
Mounting Sequence
47
Inserting and Removing Devices
49
Inserting the I/O Module
49
Figure 8: Insert I/O Module (Example)
49
Figure 9: Snap the I/O Module into Place (Example)
49
Removing the I/O Module
50
Figure 10: Removing the I/O Module (Example)
50
I/O Modules with Pluggable Wiring Level (Series 753)
51
Figure 11: Plug and I/O Module
51
Figure 12: Assignment of I/O Module to Plug Using Mini-WSB Tags
51
Coding
52
Figure 13: Attachment of Cable Binders
52
Figure 14: Assembling the Coding Fingers
52
Figure 15: Inserting the Coding Fingers
52
Figure 16: Plugging the Plug into Place
53
Figure 17: "Sure Match" Coding Fingers
53
Plug Removal
54
Figure 18: Pulling the Pull Tab
54
Figure 19: Removing the Plug Without Tools
54
Figure 20: Removing the Plug Using a Screwdriver
54
7 Connect Devices
55
Connecting a Conductor to the CAGE CLAMP
55
Figure 21: Connecting a Conductor to a CAGE CLAMP
55
Connection Examples
56
Figure 22: Connection Example - 2-Wire Connection
56
Figure 23: Connection Example - 2-Wire Connection for Energy Saving Mode
56
8 Commissioning
57
Preparation
57
Table 23: Example of a Fieldbus Node Setup
57
Configuration and Parameterization
58
IEC Function Block Library CODESYS 2.3
58
E!Cockpit
58
WAGO SMI Configurator
59
9 Diagnostics
60
Table 24: Overview of the Diagnostics and Status Messages of the
60
List of Figures
62
List of Tables
63
Advertisement
WAGO 753-1631 Product Manual (44 pages)
SMI-Master LoVo; DC 24 V
Brand:
WAGO
| Category:
I/O Systems
| Size: 5.66 MB
Table of Contents
Table of Contents
3
Provisions
5
Scope of Applicability
5
Overview
6
Properties
7
View
7
Figure 1 View
7
Indicators
8
Figure 2 Indicators
8
Figure 3 Wiring Interface
9
Wiring Interface
9
Power Jumper Contacts
10
Figure 4 Power Jumper Contacts
10
Circuit Diagram
11
Figure 5 Circuit Diagram
11
Functions
12
Operating Modes
12
Fieldbus Coupler Mode
12
Full Mode
12
Forced Position
13
1-Button Mode
13
Digital Input
13
Fieldbus Coupler Mode
13
Signal Processing
13
2-Button Mode
14
Digital Output
14
Automatic Addressing
14
Table 1 Behavior of SMI Drives and Shutters in the Event of Button Presses
14
Auto-Replace
15
Controller Locking
15
Energy Saving Mode
15
Shutter and Slat Positioning
16
Figure 6 Schematic Representation of the Positioning of Shutters and Slats
17
Logging
17
Full Mode
17
System Expansion
18
System Image Readout
18
Extended SMI Command Set
18
Swapping Addresses and Readdressing
18
Process Image
19
Setup
19
Control and Status Bytes
19
Table 4 Extended Control Byte C1
21
Table 5 Extended Status Byte S1
21
Table 6 Output and Input Process Images in Fieldbus Coupler Mode
22
Table 2 Control Byte C0
22
Table 3 Status Byte S0
22
Local Bus Processing
22
Table 7 Commands
23
Table 8 Responses to Request Commands
24
Fieldbus Coupler Mode
26
Diagnostic Functions
26
Local Bus Communication
26
Local Bus Failure Monitoring
26
Controller Failure Monitoring
26
Power Failure Monitoring
26
Compatibility
27
Fieldbus Coupler Mode
27
Structure Guidelines
27
Behavior on Switching On/Off and in the Event of Communication Interruption
27
Buffering
27
Planning
27
Table 9 Compatibility List - Fieldbus Coupler Mode
28
Full Mode
29
Table 10 Compatibility List - Full Mode
29
E!Cockpit
30
WAGO SMI Configurator
30
CODESYS 2.3 IEC Function Block Library
30
Aids
30
Connection Examples
31
Figure 7 2-Wire Connection Example
31
Figure 8 2-Wire Connection for Energy Saving Mode
31
Commissioning
32
Configuration and Parameterization with WAGO Software
32
Preparing and Carrying out the Example Configuration
32
Table 11 Example of a Fieldbus Node Setup
32
Diagnostics Via Process Image
33
Table 12 Overview of the Diagnostics and Status Messages of the SMI Master Module
33
Behavior of the I/O Module in the Event of an Error
33
Diagnostics
33
Diagnostics Via Indicators
34
Table 13 Diagnostics Via Indicators
34
Service
36
Factory Settings
36
Firmware Update/Downgrade
36
Table 14 Factory Settings
36
Application Example
37
Use 1-Button Operating Mode
37
Appendix
38
Technical Data, Approvals, Duidelines and Standards
38
Data_Sheet_753-1631
38
List of Tables
41
Advertisement
Related Products
WAGO 753-454
WAGO I/O-SYSTEM 753-456
WAGO 753-452
WAGO 753-431
WAGO 753 Series
WAGO 753-461/003-000
WAGO 753-661/000-004
WAGO 753-482
WAGO 753-506
WAGO 753-540
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL