Sign In
Upload
Manuals
Brands
WAGO Manuals
I/O Systems
753-506
WAGO 753-506 Manuals
Manuals and User Guides for WAGO 753-506. We have
1
WAGO 753-506 manual available for free PDF download: Manual
WAGO 753-506 Manual (52 pages)
2DO 24V DC 0.5A/ diagnostics 2-Channel Digital Output; 24 V DC; Short-circuit protected; high-side switching; with diagnostics
Brand:
WAGO
| Category:
I/O Systems
| Size: 3.96 MB
Table of Contents
Table of Contents
3
Notes about this Documentation
5
Validity of this Documentation
5
Copyright
5
Symbols
6
Number Notation
8
Font Conventions
8
Table 1: Number Notation
8
Table 2: Font Conventions
8
Important Notes
9
Legal Bases
9
Subject to Changes
9
Personnel Qualifications
9
Use of the 750 Series in Compliance with Underlying Provisions
9
Technical Condition of Specified Devices
10
Disposal
10
2.1.4.1.1 Electrical and Electronic Equipment
10
2.1.4.1.2 Packaging
11
Safety Advice (Precautions)
12
Device Description
15
View
17
Figure 1: View
17
Table 3: Legend for Figure "View
17
Connectors
18
Data Contacts/Local Bus
18
Figure 2: Data Contacts
18
Power Jumper Contacts/Field Supply
19
Figure 3: Power Jumper Contacts
19
Table 4: Legend for Figure "Power Jumper Contacts
19
Cage Clamp
21
Figure 4: CAGE CLAMP ® Connectors
21
Table 5: Legend for Figure "CAGE CLAMP ® Connectors
21
Display Elements
22
Figure 5: Display Elements
22
Table 6: Legend for Figure "Display Elements
22
Schematic Diagram
23
Figure 6: Schematic Diagram
23
Technical Data
24
Device Data
24
Power Supply
24
Communication
24
Outputs
24
Table 7: Technical Data - Device
24
Table 8: Technical Data - Power Supply
24
Table 9: Technical Data - Communication
24
Table 10: Technical Data - Outputs
24
Connection
25
Climatic Environmental Conditions
25
Table 11: Technical Data - Field Wiring
25
Table 12: Technical Data - Power Jumper Contacts
25
Table 13: Technical Data - Data Contacts
25
Table 14: Technical Data - Climatic Environmental Conditions
25
Approvals
26
Standards and Guidelines
27
Process Image
28
Table 15: Output Bits
28
Table 16: Input Bits
28
Mounting
29
Mounting Sequence
29
Inserting and Removing Devices
30
Inserting the I/O Module
30
Figure 7: Insert I/O Module (Example)
30
Figure 8: Snap the I/O Module into Place (Example)
30
Removing the I/O Module
31
Figure 9: Removing the I/O Module (Example)
31
I/O Modules with Pluggable Wiring Level (Series 753)
32
Figure 10: Plug and I/O Module
32
Figure 11: Assignment of I/O Module to Plug Using Mini-WSB Tags
32
Coding
33
Figure 12: Attachment of Cable Binders
33
Figure 13: Assembling the Coding Fingers
33
Figure 14: Inserting the Coding Fingers
33
Figure 15: Plugging the Plug into Place
34
Figure 16: "Sure Match" Coding Fingers
34
Plug Removal
35
Figure 17: Pulling the Pull Tab
35
Figure 18: Removing the Plug Without Tools
35
Figure 19: Removing the Plug Using a Screwdriver
35
Connect Devices
36
Connecting a Conductor to the CAGE CLAMP
36
Figure 20: Connecting a Conductor to a CAGE CLAMP
36
Connection Examples
37
2-Conductor Connection, Ungrounded
37
2-Conductor Connection, Grounded
37
Figure 21: Connecting Diagram, 2-Conductor Connection, Ungrounded
37
Figure 22: Connecting Diagram, 2-Conductor Connection, Grounded
37
3-Conductor Connection, Ungrounded
38
3-Conductor Connection, Grounded
38
Figure 23: Connecting Diagram, 3-Conductor Connection, Ungrounded
38
Figure 24: Connecting Diagram, 3-Conductor Connection, Grounded
38
Use in Hazardous Environments
39
Marking Configuration Examples
40
Marking for Europe According to ATEX and Iecex
40
Figure 25: Marking Example Per ATEX and Iecex
40
Figure 26: Text Detail - Marking Example Per ATEX and Iecex
40
Table 17: Description of the Marking Example Per ATEX and Iecex
41
Figure 27: Marking Example of an Approved I/O Module Ex I Per ATEX and
42
Figure 28: Text Detail - Marking Example of an Approved I/O Module Ex I Per
42
Table 18: Description of the Marking Example of an Approved I/O Module Ex I Per ATEX and Iecex
43
Marking for the United States of America (NEC) and Canada (CEC)
44
Figure 29: Marking Example According to NEC
44
Figure 30: Text Detail - Marking Example According to NEC 500
44
Table 19: Description of Marking Example According to NEC 500
44
Figure 31: Text Detail - Marking Example for Approved I/O Module Ex I
45
Figure 32: Text Detail - Marking Example for Approved I/O Module Ex I
45
Table 20: Description of Marking Example for Approved I/O Module Ex I
45
Table 21: Description of Marking Example for Approved I/O Module Ex I
45
Figure 33: Text Detail - Marking Example for Approved I/O Module Ex I
46
Table 22: Description of Marking Example for Approved I/O Module Ex I
46
Installation Regulations
47
Special Notes Including Explosion Protection
47
Special Notes Regarding UL Hazardous Location
49
List of Figures
50
List of Tables
51
Advertisement
Advertisement
Related Products
WAGO 753-540
WAGO 753-454
WAGO I/O-SYSTEM 753-456
WAGO 753-452
WAGO 753-431
WAGO 753 Series
WAGO 753-461/003-000
WAGO 753-661/000-004
WAGO 753-1631
WAGO 753-482
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL