1662/1664 Barcode Scanner

1.18 HARDWARE RESET

1.18.1 RESTORE SYSTEM DEFAULTS

In addition to scanning the "Restore System Defaults" barcode, the following procedure
using key combinations, can be used to restore the system defaults during operation.
1) Hold down the [Power/Delete] key.
2) When the scanner responds with two short beeps (high tone), press the [Trigger] key
for 5 seconds. The scanner LED indicator becomes solid red and then goes off.
3) When the scanner responds with a long beep (high tone), release the keys. Its LED
indicator becomes solid red and goes off.
Note: The scanner will restart itself automatically.

1.18.2 RESET CONNECTION

When the output interface is Bluetooth
attempt to maintain an established connection. To stop such re-connection, read the
"Reset Connection" or "Restore System Defaults" barcode to clear the current connection
record. Alternatively, use the key combination as described below to reset connection
during operation.
1) Hold down the [Trigger] key, and then press the [Power/Delete] key for at least 5
seconds.
2) The scanner will respond with two short beeps (high tone). Wait until the scanner
responds with a long beep (high tone), and then release the keys.
Note: After resetting connection by hardware, the scanner will not restart itself
automatically. It will resume to its previous operation except no connection.

1.18.3 DISABLE HARDWARE RESET

By default, the key combination for hardware reset (including system defaults restoration
and connection reset) is enabled. Users can decide whether to enable/disable the key
combination.