Page 1
Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. ...
Page 2
CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free.
Page 3
RELEASE NOTES VERSION DATE NOTES 2.21 Jan. 02, 2008 Larger setup barcodes 2.20 Nov. 30, 2007 New Word template applied New: 3667 Bluetooth Cradle for 1166/1266 Modified: Auto-Sense mode supported on 1100 only. New: Appendix III – Host Serial Commands New: Appendix IV –...
OVERVIEW ENTER CONFIGURATION MODE Serial Command Enter Setup EXIT CONFIGURATION MODE UPDATE SETTINGS Serial Command 9999 Update EXIT WITHOUT CHANGES Serial Command 9998 Abort RESTORE DEFAULTS Serial Command 9993 Restore Defaults Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”. Update...
Scanner Configuration SmartScan Manual LIST CURRENT SETTINGS List settings regarding Interface, Buzzer, and Serial Command 9950 Scanner Parameters Page 1 List settings regarding Prefix, Postfix, and Serial Command 9951 Length Code Setting Page 2 Serial Command List settings regarding Code ID...
Chapter 1 BLUETOOTH SETTINGS (1166/1266) 1.1 RF AUTO SHUTDOWN (SUSPEND MODE) 1) Read this label to specify the time interval before the scanner enters suspend mode. 2) Read the “Decimal Value” label on page 57. For example, read “1” and “5” for the scanner to suspend the connection with 3666 after being idle for 15 minutes.
Scanner Configuration SmartScan Manual 1.4.2 SEND DATA Serial Command 9918 Send Data 1.4.3 CLEAR DATA 1) Read the “Clear Data” label to clear the flash memory. 2) Read the “Confirm” label to confirm the action. Serial Command Serial Command 9916...
Chapter 1 Bluetooth Settings (1166/1266) 1.5 SET CONNECTION WITH 3666 1) Read this label or the same one at the bottom of the 3666 cradle. 2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds. 3) Proceed to select a desired output interface.
Scanner Configuration SmartScan Manual 1.6.2 BLUETOOTH HID PARAMETERS 1) Read this label to activate Bluetooth HID and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type.
Page 15
Chapter 1 Bluetooth Settings (1166/1266) PIN CODE 1) Read this label to specify the PIN code. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed). 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0452 Enter PIN Code …...
Page 16
Scanner Configuration SmartScan Manual CAPITAL LOCK SETTING Serial Command Serial Command 0002 0003 Auto Detection Capital Lock ON Serial Command 0004 <Capital Lock OFF> ALPHABETS TRANSMISSION Serial Command Serial Command 0005 0006 Ignore Case <Case-Sensitive> DIGITS TRANSMISSION Serial Command Serial Command...
Scanner Configuration SmartScan Manual Serial Command Serial Command 0068 0069 Auto Power Off Mode Alternate Mode Serial Command Serial Command 0070 0071 Momentary Mode Repeat Mode Serial Command Serial Command 0072 0073 <Laser Mode> Test Mode (Default for 1100/1105/1166/1200/1266) 2.4 AUTO-SENSE MODE (1100 ONLY)
Chapter 2 Reader Settings Serial Command Serial Command 0338 0339 <400 ms> 800 ms Serial Command Serial Command 0340 0341 1 sec 2 sec Serial Command Serial Command 0342 0343 3 sec 5 sec 2.7 NEGATIVE BARCODE SETTING Serial Command Serial Command 0199 0200...
Page 20
Scanner Configuration SmartScan Manual Enter Setup...
Chapter 3 OUTPUT INTERFACES 3.1 KEYBOARD WEDGE PARAMETERS 3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE 1) Read this label to activate Keyboard Wedge and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type.
Chapter 3 Output Interfaces 3.1.6 ALPHABETS TRANSMISSION Serial Command Serial Command 0005 0006 Ignore Case <Case-Sensitive> 3.1.7 DIGITS TRANSMISSION Serial Command Serial Command 0013 0014 Numeric Key <Alphanumeric Key> 3.1.8 ALT COMPOSING Serial Command Serial Command 0335 0334 <No> 3.1.9 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay.
Chapter 3 Output Interfaces 3.2.4 DATA BITS Serial Command Serial Command 0034 0035 <8 bits> 7 bits 3.2.5 FLOW CONTROL Serial Command Serial Command 0042 0043 <None> Scanner Ready Serial Command Serial Command 0044 0045 Data Ready Invert Data Ready 3.2.6 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay.
Scanner Configuration SmartScan Manual 3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200) 3.3.1 ACTIVATE WAND EMULATION Serial Command 0306 Activate Wand Emulation 3.3.2 NORMAL STATE Serial Command Serial Command 0302 0303 High <Low> 3.3.3 BAR STATE Serial Command Serial Command 0304 0305 <High>...
Chapter 3 Output Interfaces 3.3.5 MARGIN TIME Serial Command Serial Command 0370 0371 5 ms 10 ms Serial Command Serial Command 0372 0373 <20 ms> 30 ms Serial Command Serial Command 0374 0375 40 ms 60 ms Serial Command Serial Command 0376 0377 80 ms...
Page 28
Scanner Configuration SmartScan Manual Enter Setup...
Scanner Configuration SmartScan Manual CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
Page 37
Chapter 4 Symbology Settings CHECKSUM VERIFICATION Serial Command Serial Command 0147 0148 Enable <Disable> CHECKSUM TRANSMISSION Serial Command Serial Command 0149 0150 <Enable> Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max.
Chapter 4 Symbology Settings 4.9 EAN-128 PARAMETERS Serial Command Serial Command 0104 0105 Enable <Disable> CODE ID TRANSMISSION Serial Command Serial Command 0434 0435 Enable <Disable> FIELD SEPARATOR Serial Command 0301 Enable Field Separator … 1) Read this label to enable field separator. 2) Read the “Hexadecimal Value”...
Chapter 4 Symbology Settings 4.12 PLESSEY PARAMETERS Serial Command Serial Command 0114 0115 Enable <Disable> CONVERT TO UK PLESSEY Serial Command Serial Command 0165 0166 Enable <Disable> CHECKSUM TRANSMISSION Serial Command Serial Command 0163 0164 <Enable> Disable Update...
Scanner Configuration SmartScan Manual 4.13 RSS FAMILY PARAMETERS CODE ID SELECTION Serial Command Serial Command 0432 0433 <]e0> 4.13.1 RSS-14 Serial Command Serial Command 0412 Enable RSS-14 & RSS <Disable Both> Expanded CODE ID TRANSMISSION Serial Command Serial Command 0418 0419 <Enable>...
Chapter 4 Symbology Settings CODE ID TRANSMISSION Serial Command Serial Command 0420 0421 <Enable> Disable APPLICATION ID TRANSMISSION Serial Command Serial Command 0426 0427 <Enable> Disable CHECKSUM TRANSMISSION Serial Command Serial Command 0430 0431 <Enable> Disable 4.13.3 RSS EXPANDED Serial Command Serial Command 0412 Enable RSS-14 &...
Scanner Configuration SmartScan Manual 4.14 TELEPEN PARAMETERS Serial Command Serial Command 0436 0437 Enable <Disable> TELEPEN OUTPUT Serial Command Serial Command 0440 0441 Original Telepen <AIM Telepen> (Numeric) APPLY ALL 3 EDITING FORMATS Serial Command Serial Command 0443 0444 <Apply All to Telepen>...
Chapter 5 DATA OUTPUT FORMAT 5.1 CHARACTER SUBSTITUTION 1) Read the label to enable either character substitution by set. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-]. 3) Read the “Validate”...
Scanner Configuration SmartScan Manual 5.3.2 SELECT PRE-DEFINED CODE ID Serial Command Serial Command 9961 9962 Code ID Set 1 Code ID Set 2 Serial Command Serial Command 9963 9964 Code ID Set 3 Code ID Set 4 Serial Command 9965 Code ID Set 5 5.3.3 CHANGE CODE ID...
Chapter 5 Data Output Format Serial Command Serial Command 0261 0268 Matrix 25 Serial Command Serial Command 0269 0442 Plessey Telepen Serial Command Serial Command 0270 0265 UPC-A UPC-E 5.4 LENGTH CODE SETTING CODABAR Serial Command Serial Command 0236 0237 Enable Length Code <Disable Length Code>...
Page 54
Scanner Configuration SmartScan Manual EAN-8 Serial Command Serial Command 0244 0245 Enable Length Code <Disable Length Code> EAN-13 Serial Command Serial Command 0246 0247 Enable Length Code <Disable Length Code> FRENCH PHARMACODE Serial Command Serial Command 0228 0229 Enable Length Code <Disable Length Code>...
Page 55
Chapter 5 Data Output Format Serial Command Serial Command 0248 0249 Enable Length Code <Disable Length Code> PLESSEY Serial Command Serial Command 0250 0251 Enable Length Code <Disable Length Code> TELEPEN Serial Command Serial Command 0438 0439 Enable Length Code <Disable Length Code>...
Page 56
Scanner Configuration SmartScan Manual Enter Setup...
Chapter 6 DATA EDITING 6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS FORMAT 1 Serial Command Serial Command 0281 0282 Enable Editing Format 1 <Disable Editing Format 1> FORMAT 2 Serial Command Serial Command 0283 0284 Enable Editing Format 2 <Disable Editing Format 2>...
Scanner Configuration SmartScan Manual 6.2 EDITING FORMAT PARAMETERS 6.2.1 SELECT FORMAT TO CONFIGURE START FORMAT PROGRAMMING Serial Command Serial Command 9981 9982 Configure Format 1 Configure Format 2 Serial Command 9983 Configure Format 3 END FORMAT PROGRAMMING Serial Command 9980 End Format Programming 6.2.2 RESTORE DEFAULT FORMAT...
Page 59
Chapter 6 Data Editing Serial Command Serial Command 0524 0526 EAN-8 No Addon EAN-8 Addon 2 Serial Command Serial Command 0528 0532 EAN-8 Addon 5 EAN-13 No Addon Serial Command Serial Command 0534 0536 EAN-13 Addon 2 EAN-13 Addon 5 Serial Command Serial Command 0590...
Scanner Configuration SmartScan Manual 2) Read the “Decimal Value” label on page 57 for the desired length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command Serial Command 0548 0549 Max. Length Min. Length MATCHING STRING 1) Read the label to specify a matching string.
Page 61
Chapter 6 Data Editing FIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0555 Select Field Terminating String …...
Page 62
Scanner Configuration SmartScan Manual Serial Command 0558 Divide Field by Field Length … FIELD 3 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
Chapter 6 Data Editing 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0566 Divide Field by Field Length … FIELD 5 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value”...
Scanner Configuration SmartScan Manual Serial Command 0576 Additional Field 5… 6.2.6 FIELD TRANSMISSION SEQUENCE 1) Read the “Start” label to begin with programming the field transmission sequence. 2) Program the transmission sequence by reading the desired fields as well as additional fields.
Appendix I NUMERAL SYSTEMS DECIMAL SYSTEM DECIMAL Serial Command Serial Command 9900 9901 Serial Command Serial Command 9902 9903 Serial Command Serial Command 9904 9905 Serial Command Serial Command 9906 9907 Serial Command Serial Command 9908 9909 VALIDATE THE VALUES Serial Command 9994 Validate...
Scanner Configuration SmartScan Manual HEXADECIMAL SYSTEM HEXADECIMAL Serial Command Serial Command 9900 9901 Serial Command Serial Command 9902 9903 Serial Command Serial Command 9904 9905 Serial Command Serial Command 9906 9907 Serial Command Serial Command 9908 9909 Serial Command Serial Command...
Appendix II KEYBOARD WEDGE TABLE & ASCII TABLE KEYBOARD WEDGE TABLE " Home Down & Left Right PgUp Exec < PgDn > ENTER* Note: (1) ~ : Digits of numeric keypad. (2) CR*/Send/ENTER*: ENTER key on the numeric keypad. KEY TYPE Serial Command Serial Command 9926...
Scanner Configuration SmartScan Manual KEY STATUS Serial Command Serial Command 9930 9931 Add Shift Add Left Ctrl Serial Command Serial Command 9932 9933 Add Left Alt Add Right Ctrl Serial Command 9934 Add Right Alt Note: Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.
Appendix III HOST SERIAL COMMANDS SERIAL COMMANDS #@nnnn<CR> Purpose To configure the scanner. Remarks nnnn – the four digits of command parameters. For example, “9952” is to list the current Code ID settings. “0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” #@ - - - -<CR>...
Page 70
Scanner Configuration SmartScan Manual For the scanner to change the buzzer frequency to 4 kHz and beep – #@0047<CR> #@////<CR> For the scanner to change the buzzer frequency to 1 kHz and beep – #@0049<CR> #@////<CR>...
Appendix IV UPGRADING FIRMWARE HOW TO UPGRADE 1166/1266 FIRMWARE You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest scanners when there is more than one scanner connected to your computer, either via (1) the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle.
Scanner Configuration SmartScan Manual Enter Setup Download 6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer. (Download.exe requires version 2.3 or later!) Open the firmware update “1x66-xx.shx”, and select the correct COM port. Baud rate – 115,200 bps Data bit –...
Appendix IV Upgrading Firmware HOW TO UPGRADE 3666 FIRMWARE 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle.
Page 74
Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.
Need help?
Do you have a question about the SmartScan and is the answer not in the manual?