Reg - Polycom CX5500 Administrator's Manual

Unified conference station for microsoft lync
Hide thumbs Also See for CX5500:
Table of Contents

Advertisement

Polycom CX5500 Unified Conference Station Administrator's Guide
Parameter
1
qos.ip.rtp.video.dscp
Allows the DSCP of packets to be specified. If the value is non-null, this parameter will override the other
qos.ip.rtp.video.*parameters. The default value is Null, so the other qos.ip.rtp.video.* parameters
will be used.
qos.ip.rtp.video.max_reliability
qos.ip.rtp.video.max_throughput
qos.ip.rtp.video.min_cost
qos.ip.rtp.video.min_delay
qos.ip.rtp.video.precedence
Set the bits in the IP ToS field of the IP header used for RTP video. Specify whether or not to set the max
reliability bit, the max throughput bit, the min cost bit, the min delay bit, and the precedence bit.
If 0, the bit in the IP ToS field of the IP header is not set. If 1, the bit is set.
1
Change causes phone to restart or reboot.
<reg/>
Each registration can optionally be associated with a private array of servers for completely segregated
signaling. The CX5500 system supports a total of 16 registrations.
In the following tables, x is the registration number. For the CX5500, x=1-16.
The tables
Registration Parameters
registration parameters.
Registration Parameters
Parameter
reg.x.acd-login-logout
reg.x.acd-agent-available
If both ACD login/logout and agent available are set to 1 for registration x, the ACD feature will be enabled for that
registration.
reg.x.address
The user part (for example, 1002) or the user and the host part (for example, 1002@polycom.com) of the
registration SIP URI extension.
reg.x.applyServerDigitMapLocally
reg.x.server.y.specialInterop
If 1 and
Microsoft Lync Server. Any dialed number will apply the dial plan locally.
If 0, the dialplan from the Microsoft Lync Server is not used.
Polycom, Inc.
Permitted Values
0 to 63 or EF or any of AF11,AF12,
AF13,AF21, AF22,AF23, AF31,AF32,
AF33,AF41, AF42,AF43
1
0 or 1
1
0 or 1
1
0 or 1
1
0 or 1
1
0 -7
and
Registration Server Parameters
is set to
list all line registration and server
Permitted Values
Default
0 or 1
0
0 or 1
0
string address
Null
0 or 1
0
lync2010
, the phone uses the dialplan from the
1.1.0
Default
Null
0
1
0
1
5
285

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents