Polycom CX5500 Unified Conference Station Administrator's Guide
Logging Schedule Parameters
Parameter
log.sched.x.level
Event class to assign to the log events generated by this command. This needs to be the same or higher than
log.level.change.slog for these events to display in the log.
log.sched.x.name
Name of an internal system command to be periodically executed. To be supplied by Polycom.
log.sched.x.period
Seconds between each command execution. 0=run once
log.sched.x.startDay
When startMode is abs, specifies the day of the week to start command execution. 1=Sun, 2=Mon, ..., 7=Sat
log.sched.x.startMode
Start at an absolute time or relative to boot.
log.sched.x.startTime
Seconds since boot when startMode is rel or the start time in 24-hour clock format when startMode is abs.
<msg/>
The table
Message Waiting Parameters
is supported on a per-registration basis.
In the following table, x is the registration number. For the CX5500, x=1-16.
Message Waiting Parameters
Parameter
msg.bypassInstantMessage
This parameter determines what is shown on the phone menu when you press the Messages key. If 0, the
phone shows Message Center and Instant Messages. If 1, the phone bypasses these menus and goes directly to
voicemail.
msg.mwi.x.subscribe
If non-Null, the phone will send a SUBSCRIBE request to this contact after boot-up.
Polycom, Inc.
lists parameters you can use to configure message-waiting which
Permitted Values
1
0 or 1
ASCII encoded string containing digits (the
user part of a SIP URL) or a string that
constitutes a valid SIP URL (6416 or
6416@polycom.com)
Permitted Values
0 to 5, default 3
alphanumeric string
positive integer, default 15
0 to 7
abs, rel
positive integer OR hh:mm
1.1.0
Default
0
Null