Restart Scenarios
8. When the telephone determines that the application file received is valid, the following
message displays:
File Obtained;please wait...
s secs
where s is the number of seconds that elapse while non-volatile memory is erased.
9. The following message displays while the application file is stored in flash memory:
Saving to flash
n%, x secs
where n is the percentage of the file that was stored, and x is the number of elapsed
seconds. This usually takes longer than the file's download.
10. The telephone is reset so the new system-specific application file can be executed.
11. Continue with the next procedure.
Latest Boot File and System-Specific
Application File Already Loaded
This happens with normal resets.
1. The telephone displays:
Restarting...
2. The telephone detects and displays the speed of the Ethernet interface in Mbps, that is, 0,
10, 100, 1000. The message No Ethernet displays until the software determines whether
the interface is 10 Mbps, 100 Mbps, or 1000 Mbps.
Note:
The Ethernet speed indicated is the LAN interface speed for both the telephone
Note:
and any attached PC.
3. The software determines whether sufficient IP Address information was downloaded. In this
scenario, it is discovered that sufficient information has not been downloaded. The
following message displays while the DHCP process is invoked:
DHCP: 0 secs
* to program
The number of elapsed seconds is incremented once per second, until DHCP successfully
completes.