Recovering From Loss Of Extrusion - µ-Dimension 180-00108 uPrint User Manual

Table of Contents

Advertisement

Troubleshooting and Maintenance
11. Use the 7/64 T-Handle to hold pressure against the toggle spring and keep the idler wheel away from
the material. Remove the 1/8 T-Handle.
12. Press Blower Off on the interface panel. With the head blower off the temperature of the extrusion
tube will increase.
13. After approximately 5 seconds, reduce pressure against the toggle spring and allow the idler wheel to
contact the material. Material should extrude from the clogged tip.
14. Press Stop on the interface panel.
15. Move the toggle bar to activate the drive wheel control options for the non-clogged side.
16. Press Forward on the interface panel. Make sure that material extrudes from the non-clogged extru-
sion tip.
17. Press Stop on the interface panel.
18. Install air plenum.
19. Install plastic head cover.
20. Exit Maintenance mode.

Recovering From Loss of Extrusion

1. Enter Head Maintenance mode.
A. From Idle, press Maintenance.
B. Press Next.
C. Press Head Maintenance.
Document Number 206465-0001
The blower will automatically turn on after 10 seconds.
It is necessary to confirm proper operation of the non-
clogged side. Temporarily having the blower off can
occasionally cause the non-clogged side to clog.
It is recommended that you read and understand this entire
procedure before performing any of the work.
Note:
Note:
Note:
57
User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

180-00109 uprint180-00110 uprint

Table of Contents