Remove A Part From The Modeling Base; Removing Support Material - µ-Dimension 180-00108 uPrint User Manual

Table of Contents

Advertisement

Operation
4. Close the chamber door.
5. After you have opened and closed the door, the display will show Part Removed? ONLY after remov-
ing the part and replacing the modeling base, from the display panel press Yes.
After you press Yes, the display will show the status as Idle or Ready to Build for the next part in the
queue.

Remove a part from the modeling base:

1. After removing the modeling base from the printer, firmly flex the modeling base back and forth with
your hands to loosen the part.
2. Pull the part off of the modeling base or use a putty knife to completely remove the part.

Removing support material

uPrint uses soluble support material which is designed to dissolve in a soap and water based solution.
Your part is left with a smooth and clean finish with the fine details intact. The soluble support material can
be removed by hand with relative ease, but is designed to be dissolved from your parts for hands free
finishing.
Support material is sharp, wear safety glasses and gloves when removing
Refer to the SST Process Guide for details regarding the removal of soluble support material. A copy of the
SST Process Guide can be found at
Document Number 206465-0001
If you press Yes before removing the part, the printer can be damaged.
Parts are easier to remove from the modeling base when still
warm.
http://www.uPrintDimension.com/productinformation/customerinfo
CAUTION
Note:
Warning:
support material.
42
User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

180-00109 uprint180-00110 uprint

Table of Contents