Setup; Minimum Requirements; Workspace Requirements; Facility Requirements & Environmental Specifications - µ-Dimension 180-00108 uPrint User Manual

Table of Contents

Advertisement

Setup

Minimum requirements:

Workspace requirements:

System specifications
Printer height
Printer width
Printer depth
Printer weight
Material bay height
Material bay width
Material bay depth
Material bay weight
Air circulation
Installation location
Facility requirements & environmental specifications:
Facility requirements
Dedicated outlet voltage
requirements (Nominal):
Ambient temperature:
Relative humidity:
Network connection:
Optional UPS for power
interruptions:
Heat emission
Noise level

Work station requirements:

See release notes...
Document Number 206465-0001
762mm (30 in.)
660mm (26 in.)
660mm (26 in.)
59 Kg (130 lbs.)
153mm (6 in.)
660mm (26 in.)
660mm (26 in.)
17 Kg (37 lbs.)
115 mm (4.5 in.) minimum space behind unit for air circulation.
153 mm (6 in.) minimum space around the printer for air circulation.
Stable flat surface capable of holding 100Kg (220 lbs).
100-120 VAC, 50/60 Hz, 15 Amp minimum (20 Amp recom-
mended)
–or–
200-240 VAC, 50/60 Hz, 7 Amp minimum (10 Amp recommended)
15-30°C (60-86°F) Operating
30-70%, Non-condensing Operating
Ethernet 10/100 Base T
Rated Power – 1440 VA
Output Power – 1500 watts
3050 BTU/hr while powering up
2550 BTU/hr while building
55dBA while idle and 62dBA while operating
http://www.uPrintDimension.com/productinformation/customerinfo
12
Setup
User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

180-00109 uprint180-00110 uprint