Preventive Maintenance

69
Preventive Maintenance

Daily

Empty the purge bucket

Empty the purge bucket after each build has completed.

Inspect the tip wipe assembly

After each build you should inspect the tip wipe assembly to make sure there is no material build up. If
there is material build up, clean the tip wipe assembly. Material build up on the tip wipe assembly can
cause part quality issues. See
"Tip wipe assembly" on page 60

Inspect the tip shields

After each build you should inspect the tip shields for damage or material build up. If there is material build
up remove it as needed. If the material will not break free or there is damage to the tip shield, replace the
tip shield. See
"Tip shield replacement" on page 61

Remove Debris Buildup

Remove all material buildup on the Z platform and around the lead screw. Failure to do so could cause the
base to not be level or the Z platform to jam at its upper limit.

Vacuum Build Chamber

Vacuum the build chamber to remove all debris and purged material.

Clean Door

Do not use ammonia based glass cleaner on the door. It will damage the acrylic window.
CAUTION
ONLY use acrylic cleaner.

500 Hour maintenance

Replace the tip wipe assembly

See "Tip wipe assembly" on page 60.

Replace the tip shields

See "Tip shield replacement" on page 61.