µ-Dimension 180-00108 uPrint User Manual page 65

Table of Contents

Advertisement

Troubleshooting and Maintenance
Align the tip shield so the slotted end is
facing the back of the printer
2. With gloved hand, insert the new tip into the heater block. With the slotted side towards the rear of the
printer. See
Figure 55.
Push the tips up to
install
3. Use needle nose pliers to grasp the stainless steel shield of the tip.
4. Pull the tip shield toward you, then lift up to install the tip.
5. Push the tip toward the back of the printer once it is all the way up against the heater block.
6. Verify the tip is fully inserted into the heater block and that the stainless steel shield is aligned (See
Figure
56).
7. Use 7/64 T-Handle Allen wrench to firmly tighten the heater block clamp screws. See
Document Number 206465-0001
Figure 54: Tip shield alignment
Figure 55: Install the tips
Heater block
Figure 56
User Guide