reset alarm urgent
reset slot
schedule reboot at
Command Reference Guide
delay, undo schedule reboot.
Example
Remove the interface card at slot 3.
<NEC-PHILIPS>remove slot 3
Syntax
reset alarm urgent
View
User view
Parameter
None
Description
Using the reset alarm urgent command, you can clear all the stored alarms.
Example
Clear the all the stored alarms.
<NEC-PHILIPS> reset alarm urgent
Syntax
reset slot slot-number
View
User view
Parameter
slot-number: The number of the slot to be reset.
Description
Using the reset slot command, you can reset the device in a specified slot.
Example
Reset the device in slot 3.
<NEC-PHILIPS> reset slot 3
Syntax
schedule reboot at hh:mm [ yyyy/mm/dd ]
View
User view
Parameter
hh:mm: Reboot time of the router, in the format of "hour: minute" The hh ranges
from 0 to 23, and the mm ranges from 0 to 59.
yyyy/mm/dd: Reboot date of the router, in the format of "year/month/day. The
yyyy ranges from 2000 to 2099, the mm ranges from 1 to 12, and the value of
dd is related to the specific month.