Atm E3/T3 Interface Configuration Commands - NEC SOPHO IP 5000 Command Reference Manual

Table of Contents

Advertisement

display controller t3
4.10

ATM E3/T3 Interface Configuration Commands

cable
Command Reference Guide
By default, the CT3 interface is working in channelized mode.
Only when the CT3 interface is working in channelized mode can you configure
the T1 lines on it.
When the CT3 interface is working in unchannelized mode, the system
automatically creates a serial interface numbered serial number / 0:0 for it. This
interface operates at 44.736 Mbps and has the same logic features of a
synchronous serial interface on which you can make other configurations.
Example
Configure the interface T3 1/0/0 to work in unchannelized mode.
[NEC-PHILIPS-T3 1/0/0]using t3
Syntax
display controller t3 interface-number
View
Any view
Parameter
interface-number: CT3 interface number.
Description
Using the display controller t3 command, you can view the state information
of a CT3 interface.
In addition to the state information of the CT3 interface, the command can
display the information of each T1 line on the CT3 interface if the interface is
working in CT3 mode.
Example
Display the information related to the interface T3 1/0/0.
[NEC-PHILIPS]display controller t3 1/0/0
T3 1/0/0 is down
Description : NEC-PHILIPS Routers, T3 1/0 Interface
Frame-format C-BIT Parity, line code B3ZS, cable 49 feet, clock slave,
loopback not set
Alarm: none
ERROR: 0 BiPolarViolation , 0 EXcessiveZero, 1 FrameError
0 ParityBitError, 0 C-BitParityBitError, 0 FarEndBlockError
Syntax
cable { long | short }
undo cable
View
ATM T3 Interface view
Parameter
long: Long distance mode. Cable length ranges from 151 to 500 meters.
short: Short distance mode. Cable length ranges from 0 to 150 meters.
SOPHO