NEC SOPHO IP 5000 Command Reference Manual page 136

Table of Contents

Advertisement

controller e1
display controller e1
Command Reference Guide
Parameter
ami: Adopts Alternate Mark Inversion (AMI) line code format.
hdb3: Adopts High Density Bipolar 3 (HDB3) line code format. This parameter
is only significant for a CE1/PRI interface.
Description
Using the code command, you can set the line code format for a CE1/PRI
interface. Using the undo code command, you can restore the default line code
format of the interface.
The line code format of CE1/PRI interface defaults to hdb3.
You should keep the line code format of the interface in consistency with that
used by the remote device.
Example
Set the line code format of the interface E1 3/0/0 to ami.
[NEC-PHILIPS-E1 3/0/0]code ami
Syntax
controller e1 number
View
System view
Parameter
number: The CE1/PRI interface number.
Description
Using the controller e1 command, you can enter a CE1/PRI interface view.
Example
Enter the view of the interface E1 3/0/0.
[NEC-PHILIPS]controller E1 3/0/0
[NEC-PHILIPS-E1 3/0/0]
Syntax
display controller [ e1 number ]
View
Any view
Parameter
number: Interface number.
Description
Using the display controller e1 command, you can display the information
related to a CE1/PRI interface.
Executing this command will display the following information:
The physical state of interface
The clock mode of interface
The frame check mode of interface
And the line code format of interface