Fundamental Ct3 Interface Configuration Commands - NEC SOPHO IP 5000 Command Reference Manual

Table of Contents

Advertisement

4.9

Fundamental CT3 Interface Configuration Commands

cable
Command Reference Guide
Parameter
e3: Sets the CE3 interface to work in unchannelized mode.
ce3: Sets the CE3 interface to work in channelized mode.
Description
Using the using command, you can configure the operating mode of a CE3
interface. Using the undo using command, you can restore the default setting.
By default, the CE3 interface is working in channelized mode.
Only when the CE3 interface is working in channelized mode can you configure
the E1 lines on it.
When the CE3 interface is working in unchannelized mode, the system
automatically creates a serial interface numbered serial number / 0:0 for it. This
interface operates at 34.368 Mbps and has the same logic features of a
synchronous serial interface on which you can make other configurations.
For related command, see controller e3.
Example
Configure the interface E3 1/0/0 to work in unchannelized mode.
[NEC-PHILIPS-E3 1/0/0]using e3
Syntax
cable feet
undo cable
View
CT3 interface view
Parameter
feet: Cable length in the range of 0 to 450 feet.
Description
Using the cable command, you can configure the length of the cable with which
a
CT3 interface is connected. Using the undo cable command, you can
restore the
default length of the cable with which the CT3 interface is
connected.
The parameter feet defaults to 49.
The length of the cable for CT3 interface connection refers to the distance
between the router and the cable distribution rack.
Example
Set the cable length to 50 feet for the interface T3 1/0/0.
[NEC-PHILIPS-T3 1/0/0]cable 50