clock
code
Command Reference Guide
Only one timeslot bundling mode can be supported on one CT1/PRI interface
during a time period. In other words, this command cannot be used together
with the pri-set command.
For a related command, see pri-set.
Example
Bundle the timeslots 1, 2, 5, 10-15and 18 of the CE1/PRI interface into
channel-set 0.
[NEC-PHILIPS-T1 1/0/0]channel-set 0 timeslot-list 1,2,5,10-15,18
Syntax
clock { master | slave }
undo clock
View
CT1/PRI interface view
Parameter
master: Adopts the internal clock mode.
slave: Adopts the line clock mode.
Description
Using the clock command, you can set the clock mode on a CT1/PRI interface.
Using the undo clock command, you can restore the default clock mode on the
interface.
By default, the CE1/PRI interface adopts the line clock mode (slave).
When a CT1/PRI interface is working as DCE, chose the internal clock for it,
that is, master clock mode. When it is working as DTE, chose the line clock,
that is, the slave clock mode for it.
Example
Set the clock mode of the CT1/PRI interface to internal clock (master) mode.
[NEC-PHILIPS-T1 1/0/0] clock master
Syntax
code { ami | b8zs }
undo code
View
CT1/PRI interface view
Parameter
ami: Adopts the AMI line code format.
b8zs: Adopts the Bipolar with 8-Zero Substitution (b8zs) line code format.
Description
Using the code command, you can set the line code format for a CT1/PRI
interface. Using the undo code command, you can restore the default line code
format of the interface.
The line code format of CT1/PRI interface defaults to b8zs.