Canon iR8500 Service Manual page 782

Hide thumbs Also See for iR8500:
Table of Contents

Advertisement

E065
Main cause
The primary charging assembly, HV-DC PCB, or wiring is faulty (short cir-
cuit, open circuit).
Condition
0000 A fault (leakage) in high-voltage output to the primary charging
E067
Main cause
The HV-DC PCB is faulty. The HV-AC PCB is faulty. The wiring is faulty
(short circuit, open circuit).
Condition
0000 A fault is detected in two of the following: primary high voltage,
E068
Main cause
The HV-DC PCB is faulty. The HV-AC PCB is faulty. The separation charg-
ing assembly is faulty. The wiring is faulty (short circuit, open circuit).
Condition
0000 A fault (leakage) in high-voltage output to the separation charging
E069
Main cause
The HV-DC PCB is faulty. The HV-AC PCB is faulty. The transfer charging
assembly is faulty. The wiring is faulty (short circuit, open circuit).
Condition
0000 A fault (leakage) in the high-voltage output to the transfer charging
COPYRIGHT© 2001 CANON INC.
assembly is detected.
pre-transfer high voltage, transfer high voltage, and separation high
voltage. Or, a fault (leakage) in high-voltage output to the separa-
tion charging assembly is detected.
assembly is detected.
assembly is detected.
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
ERROR CODE
E-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir7200

Table of Contents