CHAPTER 2 NEW FUNCTIONS
8) Remove the four screws [1], and dis-
connect the connector [2]; then, free the
flat cable [3], and free the two fixing
claws [4]. Thereafter, detach the CCD
unit [5].
b. When Replacing the CCD/AP Unit
Be sure to execute 'CCD auto adjustment' in service mode, and record the updated CCD
adjustment data on the service label.
1. CCD Auto Adjustment
COPIER>FUNCTION>CCD>CCD-ADJ
2. CCD Adjustment dataall items under
COPIER>ADJUST>CCD

5.4.2 Reader Controller PCB

a. Removing the Reader Controller PCB
1) Remove the reader rear cover.
2) Disconnect the nine connectors [1], re-
move the seven screws [2], and remove
the flat cable [3]; then, detach the reader
controller PCB [4].
Do not hurt the flat cable which
is removed in step 2).
2-96
COPYRIGHT© 2001 CANON INC.
[1]
[3]
[2]
[4]
F02-504-03
[4]
[1]
[2]
[2]
F02-504-04
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
[1]
[5]
[2]
[3]
[2]

Hide quick links: