CHAPTER 2 NEW FUNCTIONS

9.6 Power Save Mode

A press on the Power Save key on the control panel decreases the control temperature
used in standby state, thereby decreasing the power consumption. F02-906-01 shows the se-
quence of operations in transparency mode.
Power save
mode selected
in user mode
Main heater
(H1)
Sub heater
(H2)
Controlled to 198˚C
198˚C
195˚C
170˚C
105˚C
2-152
Power save
key ON
STBY
SLEEP
Controlled
according to
rate of saving
Rage of saving
of 25%
Rate of saving
of 50%
F02-906-01
COPYRIGHT© 2001 CANON INC.
Power save
key OFF
195˚C
WMUP
Returns to normal temperature
control in response to a second
press on the Power Save key.
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
Omits WMUPR
198˚C
STBY