3. 6. Adjustment of Scanning Section

3. 6. 1. Carriages

(1) Installing the carriage wire

Install a new carriage wire as in the following figure when it is replaced.
[Front side]
Wire pulley
[Rear side]
Adjustment of the carriage wire tension is not necessary since a certain tension is applied to the
carriage wires by the tension springs.
Note: Make sure that the tension applied to the wire is normal.
JUNE 2002 © TOSHIBA TEC
Carriage wire
Bracket for Carriage-1
Hook
Tension spring
Idler pulley
Carriage-2
Carriage wire
Bracket for Carriage-1
3 - 25
Idler pulley
Carriage-2
Hook
Tension spring
Wire pulley