3. 11. 4. Adjustment of RADF open/close switch
When opening the RADF, adjust the bracket
position so that the switch is turned on when the
front side height becomes 40~45mm (within the
empty weight falling limit).
3. 11. 5. Adjustment of RADF height
The height is adjusted with 2 adjustment screws
at hinges.
Adjust the height so that the platen guide holders
(front, rear) touch the ADF original glass.
Platen guide holder
ADF original
glass
e-STUDIO550/650/810 ADJUSTMENT
40 ~ 45mm
Platen sheet
Original
glass
3 - 42
Adjustment screw
June 2002 © TOSHIBA TEC