Toshiba e-STUDIO650 Service Handbook page 37

Digital plain paper copier
Hide thumbs Also See for e-STUDIO650:
Table of Contents

Advertisement

Code
Items to adjust
292
Display of the output Sensor light
value of the image
quality sensor
293
296
Display of the light amount adjustment
result of the image quality sensor
305
Adjustment of scanner secondary
scanning start position deviation
306
Adjustment of scanner primary scan-
ning start position deviation
308
Distortion mode
340
Adjustment of scanner secondary
scanning reproduction ratio
354
Adjustment of
RADF paper
355
alignment
356
Automatic adjustment of RADF sen-
sor and EEPROM initialization
357
Fine adjustment of RADF transport
speed
358
RADF sideways deviation adjustment
JUNE 2002 © TOSHIBA TEC
Adjustment mode (05)
Function Default
ALL
source OFF
Drum surface
ALL
ALL
ALL
137
ALL
128
ALL
PPC
128
for single-sided
ALL
10
original
for two-sided
ALL
10
original
ALL
ALL
50
ALL
128
2 - 23 e-STUDIO550/650/810 ERROR CODES AND SELF-DIAGNOSIS
Accept-
able
Contents
value
0~1023
The output value of the image
quality sensor is displayed when
the sensor light source is OFF.
0~1023
The output value of the image
quality sensor on the drum surface
(without a test pattern) is
displayed.
0~255
LED light amount adjustment of
the sensor, which makes the light
amount reflected from the drum a
standard velue is displayed.
0~255
When the value increases by "1",
the image shifts toward the
leading edge of paper by approx.
0.1213mm.
0~255
When the value increases by "1",
image shifts toward the rear side
of paper by approx. 0.0423mm.
Moves the carriages to the
adjustment position.
(
Chapter 2.3.4.)
0~255
When the value increases by "1",
the reproduction ratio of the
secondary scanning direction
decreases by approx. 0.025%.
0~20
When the value increases by "1",
the aligning amount increases by
0~20
approx. 0.5mm.
Perform the adjustment and
initialization when the ADF board
or sensor of the RADF is
replaced.
0~100
When the value increases by "1",
the reproduction ratio of the
secondary scanning direction on
original fed from the RADF
increases by approx. 0.1%.
0~255
When the value increases by "1",
the image of original fed from the
RADF shifts toward the rear side
of paper by approx. 0.0423mm.
Operation
procedure
2
2
2
1
1
6
1
1
1
6
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio550E-studio810

Table of Contents