3. 4. 2. Sharpness adjustment for copier

When making the image sharpness softer or harder, adjust the sharpness setting in the adjustment
mode "05".
Original mode
Text/Photo
Photo
620
621
Code
The entry procedure of the adjustment value is the same as that for "3.4.1 Image density".

3. 4. 3. Gamma slope adjustment

If the user requests to change the gamma slope, perform the gamma slope adjustment in the adjustment
mode "05".
Original mode
Text/Photo
Photo
593
594
Code
The entry procedure of the adjustment value is the same as that for "3.4.1 Image density".
e-STUDIO550/650/810 ADJUSTMENT
Items to adjust
Text
622
Sharpness setting
Items to adjust
Text
595
Gamma slope adjustment
Remarks
Enter one of the following values in the original mode.
Units:
1: Text/Photo 2: Photo 5: Text
Tens:
0: Use default value
1~9: Change intensity
(The larger the value, the sharper the image
becomes.)
• Example of value entry in case the original
mode is "Text/Photo".
2 1
Note: When the value "0" is entered in the
tens digit, the value is not displayed on
the LCD screen.
0: Use default value (equivalent to the set
value 5)
1 to 9: Gamma data (The larger the value, the
darker the image becomes)
3 - 20
Fixed value for Text/Photo mode
Enter a value 0 to 9
Remarks