3. 3. 4. Scanner related adjustment

(a) Image distortion adjustment
Step 1
A
Step 2
C
1. Turn ON the power while the digital keys [0]
and [5] are pressed simultaneously.
2. Press [ENERGY SAVER] to make a copy of
any image on a sheet of A3/LD paper.
3. Enter [308] and press the [START] key to
move the carriage to the position for
adjustment (exit side).
4. Make an adjustment in the order of step 1 and
2.
[Step 1]
In the case of A: Tighten the adjustment screw
for mirror-2 (CW).
In the case of B: Loosen the adjustment screw
for mirror-2 (CCW).
[Step 2]
In the case of C: Tighten the adjustment screw
for mirror-1 (CW).
In the case of D: Loosen the adjustment screw
for mirror-1 (CCW).
e-STUDIO550/650/810 ADJUSTMENT
Feeding direction
Feeding direction
Adjustment screw
for the mirror-1
Adjustment screw
for the mirror-2
3 - 12
B
D