[C83] Original length sensor adjustment error
Is there any extraneous material between the original length sensor and reflective mirror?
YES
Remove the extraneous material.
NO
Is the reflective mirror tainted?
YES
Clean up the mirror.
NO
Is the conductor pattern around IC6, IC11 and CN15 on the ADF board short- or open-circuited?
YES
1. Replace the ADF board.
2. Perform the EEPROM initialization of RADF, sensor automatical adjustment
NO
1. Replace the original length sensor.
2. Perform the EEPROM initialization of RADF, sensor automatical adjustment and tray width
sensor adjustment.
[C84] Small original reverse sensor adjustment error
Is there any extraneous material between the small original reverse sensor and reflective mirror?
YES
Remove the extraneous material.
NO
Is the reflective mirror tainted?
YES
Clean up the mirror.
NO
Is the conductor pattern around IC6, IC11 and CN16 on the ADF board short- or open-circuited?
YES
1. Replace the ADF board.
2. Perform the EEPROM initialization of RADF, sensor automatical adjustment
NO
1. Replace the small original reverse sensor.
2. Perform the EEPROM initialization of RADF, sensor automatical adjustment and tray width
sensor adjustment.