3.
Disconnect the ADF feed drive motor cable from the ADF controller card, and remove the cable from the
clips.
Note: Observe the cable routing for reinstallation.
4.
Remove the E-clip (A) from the ADF pick roll shaft, and then remove the bushing.
7562
A
4-181