Remote Weather Station Error Service Check - Lexmark X792 Service Manual

Hide thumbs Also See for X792:
Table of Contents

Advertisement

938.28—Remote weather station error service check
Step
Questions / actions
1
Turn the printer off, and open the system
board shield. Check the cable in connector
JCCT2 (weather station compensation
thermistor) for proper connection to the
system board.
Is the cable properly connected?
2
Check the cable for damage.
Is the cable damaged?
3
Replace the weather station compensation
thermistor:
Clip the cable tie to remove the thermistor
from the LVPS.
Does the error reoccur?
Yes
Go to step 2.
Replace the weather
station compensation
thermistor. See step 3.
Replace the system board.
See
"System board
removal" on page
4-149.
7562
No
Reseat the cable.
Go to step 3.
Problem solved.
2-165
Diagnostic information
Previous
Next
Go Back

Advertisement

Table of Contents
loading

Table of Contents