Figure 90 Log tab
In this example, event 1 has generated one log, which is triggered because the alarm value
(11779194) exceeds the rising threshold (10000000). The sampling type is absolute.

RMON configuration example

Network requirements
As shown in
GigabitEthernet 1/0/1 with the sampling interval being 10 seconds. Perform corresponding
configurations so that the system logs the event when the number of bytes received on the interface more
than 1000 or less than 100.
Figure 91 Network diagram
Configuration procedure
1.
Configure RMON to gather statistics for GigabitEthernet 1/0/1:
Select Device > RMON from the navigation tree.
a.
The Statistics tab page appears.
b.
Click Add.
The page in
c.
Select GigabitEthernet1/0/1 from the Interface Name list, type user1 in the Owner field, and
click Apply.
Figure
91, create an entry in the RMON Ethernet statistics table to gather statistics on
Figure 92
appears.