Figure 88 RMON statistics
Table 28 Field description
Field
Number of Received Bytes
Number of Received Packets
Number of Received Broadcasting Packets
Number of Received Multicast Packets
Number of Received Packets With CRC Check
Failed
Number of Received Packets Smaller Than 64
Bytes
Number of Received Packets Larger Than
1518 Bytes
Number of Received Packets Smaller Than 64
Bytes And FCS Check Failed
Number of Received Packets Larger Than
1518 Bytes And FCS Check Failed
Description
Total number of octets received by the interface,
corresponding to the MIB node etherStatsOctets.
Total number of packets received by the interface,
corresponding to the MIB node etherStatsPkts.
Total number of broadcast packets received by the
interface, corresponding to the MIB node
etherStatsBroadcastPkts.
Total number of multicast packets received by the
interface, corresponding to the MIB node
etherStatsMulticastPkts.
Total number of packets with CRC errors received on the
interface, corresponding to the MIB node
etherStatsCRCAlignErrors.
Total number of undersize packets (shorter than 64
octets) received by the interface, corresponding to the
MIB node etherStatsUndersizePkts.
Total number of oversize packets (longer than 1518
octets) received by the interface, corresponding to the
MIB node etherStatsOversizePkts.
Total number of undersize packets (shorter than 64
octets) with CRC errors received by the interface,
corresponding to the MIB node etherStatsFragments.
Number of oversize packets (longer than 1518 octets)
with CRC errors received by the interface,
corresponding to the MIB node etherStatsJabbers.