5.2 Settings from the Menu
■ MENU (3/4)
Menu Item
SCAN FORMAT SELECT
SCAN MODE
CPU SYSTEM CONTROL
― SEMI SELF MODE
SEMI REMOTE MODE
AUTO IRIS SET
― IRIS SET MODE
― IRIS LEVEL SET
― PEAK RATIO SET
― IRIS GAIN
― IRIS SPEED
― IRIS LIMIT
LENS ADJUST
AWB/ABB MODE
― AWB WITH A.IRIS
― SMOOTH AWB
― AWB REFERENCE
― REFERENCE SET
AUTO WHITE SHADING
86
Initial
Setting Value
Setting
Destination
1080I59, 720P59,
setting
1080I50, 720P50
ON
ON, OFF
OFF
ON, OFF
OFF
ON, OFF
0
-100 to +100
-70
-100 to +100
50
1 to 100
50
1 to 100
F22
F22, F20, F18, F16
OFF
F16, F2.8, OFF
OFF
ON, OFF
ON-0.3s, ON-0.5s,
ON-0.7s, ON-1.0s,
ON-0.5s
ON-1.5s, ON-2.0s,
OFF
ON
ON, OFF
ABB
ABB, AWB
---
SET → START
HC-HD300 1412 VER1 (U)
Description, Remarks
Selects the camera operation format.
* If BS/CCU is connected, the format on the BS/CCU side
and the operation format will be the same.
ON : Will hold settings made by the operation control
panel when the panel is disconnected.
OFF : Will default back to camera head settings when
operation control panel is removed.
ON : Allows GAIN, AWB, and SHUTTER/SUP-V to be
set at the camera head when connected to a base
station.
OFF : Disables these functions at the camera head when
connected to a basic station.
ON : Enables auto-iris operation setting.
* If set to ON, the iris adjustment from the operation control
panel is disabled.
Adjusts the convergence level of auto iris.
Shoot the registration chart with the camera and adjust the
value so that the video level becomes 75%.
Shoot the gray scale chart with the camera and adjust the
value so that the video level is 100%.
Set the exposure for a bright area in the "+" direction and
for a dark area in the "-" direction. The default value "50"
indicates no exposure compensation.
Sets the auto-iris response sensitivity characteristics.
The auto-iris operation sensitivity is such that "1" is low and
"100" is high.
Hunting tends to occur more often as the value goes up.
(Set it to the default value"50" as long as hunting is not
occurring).
Sets the response speed characteristics of the auto-iris.
The auto-iris speed becomes slower for "1" and faster for
"100".
If the iris is about to close during auto-iris operation, it stops
the iris operation before it completely closes to prevent iris
hunting.
Sets the iris limit value at that time.
Sets the output of control voltage for fixed iris value during
lens adjustment. To adjust the relationship between the lens
control voltage value and lens iris value, the control voltage
equivalent of F2.8 and F16 can be output to the lens.
Select whether A.IRIS is automatically input or not when
executing AWB.
* This menu is only valid during self-operation. It is always
OFF during BS/CCU operation.
Switches Ach/Bch of AWB smoothly.
Transition time of swtching can be set.
ON : Converges the AWB convergence value to EXT AWB
REF.
OFF : Makes Rch/Bch correspond to Gch.
Creates convergence value of AWB and ABB
Executes AWS(Auto White Shading).
Makes Rch/Bch correspond to Gch White Shading. You must
shoot a uniformly lit white surface.