Canon imageRUNNERC1022 Service Manual page 393

Table of Contents

Advertisement

Code
E024
Toner level sensor failure
0000 Description
Failure output from the toner level sensor (Yellow).
Cause
Memory controller PCB assembly fault, DC controller PCB assembly fault, toner
cartridge fault.
0001 Description
Failure output from the toner level sensor (Magenta).
Cause
Memory controller PCB assembly fault, DC controller PCB assembly fault, toner
cartridge fault.
0002 Description
Failure output from the toner level sensor (Cyan).
Cause
Memory controller PCB assembly fault, DC controller PCB assembly fault, toner
cartridge fault.
0003 Description
Failure output from the toner level sensor (Black).
Cause
Memory controller PCB assembly fault, DC controller PCB assembly fault, toner
cartridge fault.
E066
Error in environment sensor
0000 Description
Failure in environment sensor.
Cause
Environment sensor fault, DC controller PCB assembly fault.
E078
Error in primary transfer estrangement unit
0000 Description
Primary transfer estrangement unit does not function properly.
Cause
Terminal assembly fault, transfer roller estrangement solenoid fault, EBT unit fault,
high-voltage power PCB assembly fault.
E100
Error in scanner motor, laser unit, BD
0000 Description
Yellow scanner assembly malfunction.
Cause
Laser scanner unit fault, DC controller PCB assembly fault.
0001 Description
Magenta scanner assembly malfunction.
Cause
Laser scanner unit fault, DC controller PCB assembly fault.
0002 Description
Cyan scanner assembly malfunction.
Cause
Laser scanner unit fault, DC controller PCB assembly fault.
0003 Description
Black scanner assembly malfunction.
Cause
Laser scanner unit fault, DC controller PCB assembly fault.
0004 Description
Failure output of a magenta BD signal
Cause
laser scanner unit fault, DC controller PCB fault.
0005 Description
Failure output of a magenta BD signal
Cause
laser scanner unit fault, DC controller PCB fault.
E194
Error in CPR sensor
0000 Description
Cannot detect color displacement detection pattern, detected results fall outside the
acceptable range.
Cause
Dirty color displacement detection sensor, color displacement detection sensor fault,
DC controller PCB assembly fault, toner cartridge fault.
E196
Error in DCON ROM
0001 Updating the ROM on the DC controller PCB assembly has been failed.
E197
Engine communication error
0000 Internal communication error
T-16-4
Description
Action
- Replace toner cartridge
- Replace memory controller PCB
- Replace DC controller PCB
- Replace environment sensor
- Replace DC controller PCB
- Replace ETB estrangement solenoid
- Replace ETB unit
- Terminal assembly fault (check on every contact between the
terminals of each color and the high voltage PCB assembly)
- Replace laser scanner unit
- Replace DC controller PCB
- Replace ETB unit
- Terminal assembly fault (check on every contact between the
terminals of each color and the high voltage PCB assembly)
- Replace DC controller PCB
- Replace toner cartridge
- Replace DC controller PCB
- Replace DC controller PCB
- Replace video controller PCB