Controlling The Laser Scanner Motor; Overview; Failure Detection - Canon imageRUNNERC1022 Service Manual

Table of Contents

Advertisement

Chapter 7

7.3 Controlling the Laser Scanner Motor

7.3.1 Overview

imageRUNNER C1022 / imageRUNNER C1022i / Color imageRUNNER C1030 / Color imageRUNNER C1030iF
In the DC controller, the scanner motor control is performed to emit the laser beam at the correct position on the photosensitive drum.
The scanner motor control is to rotate the scanner motor at its specified speed and phase.
- Speed control
The scanner motor is rotated at a specified speed.
- Phase control
The phase difference of the 2 polygon mirrors is adjusted while the scanner motor is rotating at a low speed to eliminate line displacement attributed to the
rotation and prevent color displacement in the sub scanning direction.
There are two scanner motors: one is for M/C and the other is for Y/Bk. The configurations of both motors are identical.
CPU
(IC1001)
The DC controller PCB generates the reference clock based on the oscillation frequency of the oscillator (X1001).
It compares the intervals between the reference clock and the BD input signal (/BD1I) sent from the laser driver PCB with the frequency comparator, and monitors
the rotational counter of the scanner motor.
It controls the rotational speed of the scanner motor by sending the scanner motor acceleration signal (/SCNMACC) or the scanner motor deceleration signal (/
SCNMDEC) to the scanner motor driver based on the detected rotational speed.

7.3.2 Failure Detection

imageRUNNER C1022 / imageRUNNER C1022i / Color imageRUNNER C1030 / Color imageRUNNER C1030iF
In the DC controller, the fault in the scanner motor is detected.
The CPU (IC1001) monitors the frequency comparator in the ASIC (IC1010) and determines whether the scanner motor rotates at its specified rotational speed or
not.
When the CPU encounters the following conditions, it determines the scanner motor failure, stops the printer engine, and displays 'E100 (optical unit failure)" on
the control panel.
- Abnormal scanner motor
The scanner motor does not enter scanner ready mode within 5 seconds of scanner motor start-up.
- BD error
- The /BDI signal cannot be detected within 1.5 seconds of once the scanner motor reached at its specified rotational speed.
- The interval of the /BDI signal goes out of the tolerance for 0.5 second continuously after the scanner motor once reached at its specified rotational speed.
7-8
DC controller PCB
+24VA
Frequency
comparator
Reference
clock
X1001
Oscillator
ASIC (IC1010)
Laser driver PCB
/BD1I
+24VA
/SCNMACC
Integration
/SCNMDEC
Scanner motor
Scanner motor drive PCB for M/C
F-7-6
BD circuit
Scanner driver IC
Drive
circuit
circuit
M
0019-5010
0019-5011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner c1030Color imagerunner c1030 seriesColor imagerunner c1022 seriesColor imagerunner c1022Color imagerunner c1022iColor imagerunner c1030 ... Show all