Specifications; Cec Drawer - IBM RS/6000 Enterprise Server M80 Service Manual

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Specifications

This section contains specifications for the system. Individual sections are provided for CEC drawer, rack,
and I/O drawer specifications.

CEC Drawer

The mechanical packaging, cooling, power supply, and environmental requirements for the CEC drawer
are shown in the following table:
Dimensions
Height
Width
Depth
Weight
Minimum
Maximum
Electrical
Power source loading typical in kVA
Power source loading maximum in kVA
Voltage range (V ac)
Frequency (hertz)
Thermal output (typical)
Thermal output (maximum)
Power requirements (typical)
Power requirements (maximum)
Power factor
Inrush current
Maximum altitude
Temperature Requirements
Humidity (Noncondensing)
Without tape drive
With tape drive
Wet Bulb Requirements
Without tape drive
With tape drive
1,2
Noise Emissions
With M80 CEC drawer only
L
WAd
L
pAm
<L
>
pA
m
Impulsive or prominent
discrete tones
1,2
Noise Emissions
With M80 and Primary I/O Drawer
L
WAd
L
pAm
<L
>
pA
m
Impulsive or prominent
discrete tones
355.6 mm
445.5 mm
825.5 mm
69.7 kg
74.6 kg
0.39
0.6
200 to 240
50 or 60
M80: 1265 Btu/hr
6M1: 772 Btu/hr
M80: 1877 Btu/hr
6M1: 1378 Btu/hr
M80: 370 watts
6M1: 226 watts
M80: 550 watts
6M1: 406 watts
0.95
34 amps
2135 m (7000 ft.)
Operating
10 to 40°C
(50 to 104°F)
Operating
8 to 80%
20 to 80%
27°C (80°F)
27°C (80°F)
Operating
6.4 bels
N/A
48 dBA
No
Operating
6.5 bels
N/A
49 dBA
No
Chapter 1. Reference Information
14.0 in.
17.5 in.
32.5 in.
158 lbs.
169 lbs.
Non-Operating (Power Off)
10 to 52°C
(50 to 125°F)
Non-Operating (Power Off)
8 to 80%
8 to 80%
27°C (80°F)
27°C (80°F)
Idle
6.4 bels
N/A
48 dBA
No
Idle
6.5 bels
N/A
49 dBA
No
59