Table 7. Service Processor Error Codes (continued)
Error Code Description
406D 0237 Attention handler detected memory DIMM
fault
406D 0238 Attention handler detected memory DIMM
fault
406D 023D Attention handler detected memory DIMM
group fault
406D 023E Attention handler detected memory DIMM
group fault
406D 023F Attention handler detected memory DIMM
group fault
406D 02FF Attention handler detected memory on riser
fault
406D 0300 Attention handler detected processor card
fault
406D 0400 Attention handler detected processor card
fault
406D 0500 Attention handler detected memory riser card
fault
406D 0501 Attention handler detected memory DIMM
fault
406D 0502 Attention handler detected memory DIMM
fault
406D 0503 Attention handler detected memory DIMM
fault
406D 0504 Attention handler detected memory DIMM
fault
406D 0505 Attention handler detected memory DIMM
fault
406D 0506 Attention handler detected memory DIMM
fault
406D 0507 Attention handler detected memory DIMM
fault
406D 0508 Attention handler detected memory DIMM
fault
406D 050D Attention handler detected memory DIMM
group fault
406D 050E Attention handler detected memory DIMM
group pair A fault
406D 050F Attention handler detected memory DIMM
group fault
406D 0511 Attention handler detected memory DIMM
fault
Action/
Possible Failing FRU
Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
Memory DIMM 32, riser 1
Location: U1.1-P1-M1.32
Memory octal D, riser 1
Location: U1.1-P1-M1.7 x8
Memory quad D odd, riser 1
Location: U1.1-P1-M1.7 x4
Memory quad D even, riser 1
Location: U1.1-P1-M1.8 x4
All memory on riser 1
Location: U1.1-P1-M1.1 x32
Memory failure on riser card 1 that cannot be
automatically isolated. go to "MAP 1540:
Minimum Configuration" on page 110 and run
CEC drawer minimum configuration for
further isolation.
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C2
Memory riser card 2
Location: U1.1-P1-M1
Memory DIMM 1, riser 2
Location: U1.1-P1-M2.1
Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18
Memory DIMM 25, riser 2
Location: U1.1-P1-M2.25
Memory DIMM 26, riser 2
Location: U1.1-P1-M2.26
Memory octal A, riser 2
Location: U1.1-P1-M2.1 x8
Memory quad A odd, riser 2
Location: U1.1-P1-M2.1 x4
Memory quad A even, riser 2
Location: U1.1-P1-M2.2 x4
Memory DIMM 3, riser 2
Location: U1.1-P1-M2.3