Step 1540-36
If the Please define the System Console screen does display and all attached devices and adapters are
listed, the problem is with one of the adapter cards or devices that was removed or disconnected from the
I/O drawer.
1. Turn off the power.
2. Replace one adapter or device that was removed. Use the original adapter cards in their original slots
when reinstalling adapters.
3. Turn on the power to boot standalone diagnostics from CD.
4. If the Please define the System Console screen is displayed, follow directions to select the system
console.
5. Use the Display Configuration and Resource List to list all attached devices and adapters (refer to the
RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems if necessary).
6. Check that all attached devices and adapters are listed.
Did the Please define the System Console screen display and are all attached devices and adapters
listed?
NO
Go to "Step 1540-37."
YES
Reinstall the next adapter or device and return to number 1 in this step. Continue repeating this
process until an adapter or device causes the Please define the System Console screen to not be
displayed or all attached devices and adapters to not be listed.
Step 1540-37
Replace the adapter or device that is causing the Please define the System Console screen to not be
displayed or all attached devices and adapters to not be listed with a new adapter.
Reinstall all remaining adapters and reconnect all devices. Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems.