Table 7. Service Processor Error Codes (continued)
Error Code Description
406C 0203 IPL MOPS detected memory DIMM fault
406C 0204 IPL MOPS detected memory DIMM fault
406C 0205 IPL MOPS detected memory DIMM fault
406C 0206 IPL MOPS detected memory DIMM fault
406C 0207 IPL MOPS detected memory DIMM fault
406C 0208 IPL MOPS detected memory DIMM fault
406C 020D IPL MOPS detected memory DIMM group
fault
406C 020E IPL MOPS detected memory DIMM group
fault
406C 020F IPL MOPS detected memory DIMM group
fault
406C 0211 IPL MOPS detected memory DIMM fault
406C 0212 IPL MOPS detected memory DIMM fault
406C 0213 IPL MOPS detected memory DIMM fault
406C 0214 IPL MOPS detected memory DIMM fault
406C 0215 IPL MOPS detected memory DIMM fault
406C 0216 IPL MOPS detected memory DIMM fault
406C 0217 IPL MOPS detected memory DIMM fault
406C 0218 IPL MOPS detected memory DIMM fault
406C 021D IPL MOPS detected memory DIMM group
fault
406C 021E IPL MOPS detected memory DIMM group
pair A fault
406C 021F IPL MOPS detected memory DIMM group
fault
406C 0221 IPL MOPS detected memory DIMM fault
406C 0222 IPL MOPS detected memory DIMM fault
406C 0223 IPL MOPS detected memory DIMM fault
Action/
Possible Failing FRU
Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4
Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
Memory DIMM 20, riser 1
Location: U1.1-P1-M1.20
Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
Chapter 5. Error Code to FRU Index
249

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents