IBM RS/6000 Enterprise Server M80 Service Manual page 284

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
406E 3101 Scan control routines detected RIO port 0
fault
406E 3102 Scan control routines detected RIO port 1
fault
406E 3103 Scan control routines detected RIO port 2
fault
406E 3104 Scan control routines detected RIO port 3
fault
406E 3121 Scan control routines detected RIO cable on
port 0 fault
406E 3122 Scan control routines detected RIO cable on
port 1 fault
406E 3123 Scan control routines detected RIO cable on
port 2 fault
406E 3124 Scan control routines detected RIO cable on
port 3 fault
406E 3140 Scan control routines detected RIO hub 0
fault
406E 3141 Scan control routines detected RIO hub 1
fault
406E 31FF Scan control routines detected RIO port fault
406E 3200 Scan control routines detected primary I/O
drawer fault
406E 3201 Scan control routines detected primary I/O
drawer backplane fault
406E 3280 Scan control routines detected primary RIO
adapter fault
406E 3281 Scan control routines detected primary RIO
port 0 fault
406E 3282 Scan control routines detected primary RIO
port 1 fault
406E 3283 Scan control routines detected primary RIO
ports fault
266
Service Guide
Action/
Possible Failing FRU
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 3
Location: U1.1-P1.1/Q4
2. CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
Go to "MAP 1540: Minimum Configuration"
on page 110.
Primary I/O drawer backplane
Location: U0.1-P1
Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. RIO bus adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. RIO bus adapter
Location: U0.1-P1.1
RIO bus adapter
Location: U0.1-P1.1